Ham-Let® H-300U needle valves are advanced high pressure instrumentation needle valves for shut-off service, its packing bolt design for easy mounting being the best solution for instrumentation panels.
Show More
These compact needle valves enable relatively high level of flow regulation and long-life service. Special stem surface treatment, based on low temperature carbon diffusion, enables higher surface hardness with improved wear resistance, resistance to system contaminations and optimal operational torque.
These H-300U needle valves were designed for high pressure services where moderately uncontaminated media is used.
For steam applications, it is recommended to select one of Ham-Let
severe service needle valves.
For relatively high pressure pure oxygen applications, assure that the
selected valve is tested and found to meet the specific application requirements.
H-300U needle valves are available with a choice of stem tips:
- Regulating: Used where some degree of flow control is required.
- V-Stem: Standard stem tip used for on/off operation in general-purpose liquids and gas service.
- Non-Rotating: Typically used in high-cycle applications to extend valve life and prevent stem rotation inside the body tip, a suitable selection for gaseous high pressure applications.
- Soft seat: soft seat tip requires lower seating torque than a metal stem tip; the best choice for clean gaseous high pressure applications. Maximum allowable working temperature is 200°F (93°C).
Testing:
- The H-300U design has been tested for Burst and Proof.
- Every H-300U needle valve is factory tested with nitrogen at 1000 psig.
- Maximum allowable leakage across the seat is 0.1 std cc/min.
Packing Adjustment:
- Due to the varied service applications of the valve, packing adjustment may occasionally
be necessary.
- Packing is factory adjusted to 1000 psig service. Initial packing adjustment is recommended after installation and prior to start-up.
- Please see packing adjustment procedure for more details.
Show Less